Dear NM-Users,

I need a method to force using EPS(1) intead ETA() for estimating
initial steady-state compartment concentration for $DES.
Pre-dose TIME for SS-ending is known. I used the following
abbreviated codes in ERROR, and NONMEM act well, but predics individual
regression stricted to measure CPZERO.

sincerely
                               Kazimierz H. Kozlowski

$DES
  DADT(1)=-K*A(1)-K12*A(1)+K21*A(2)
  DADT(2)=K12*A(1)-K21*A(2)
$ERROR
  COM(1)=ERR(1) ;QUESTION: WHY ERR(1)=0.0 in write-file and in
TABLE?
  WRITE (50,*) COM(1),ERR(1),ICALL,COMACT ; COM(1)=0, ICALL=2 always
  FZ=THETA(10)*ERR(1)*THETA(10)*ERR(1) ;FZ=ERR**2
  FZ1=1.0-FZ*THETA(9)*THETA(9) ;FZ1=1-ERR*2*TH9*2
  EXP1=(K-BETA)*EXP(-ALPHA*(IAGE+TIME))
  EXP2=(ALPHA-K)*EXP(-BETA*(IAGE+TIME))
  EXP3=ALPHA*EXP(-BETA*(IAGE+TIME))
  EXP4=BETA*EXP(-ALPHA*(IAGE+TIME))
  EN=(C01-(C01*C01-FZ1*(C01*C01-FZ))**0.5)/FZ1;EN=ENDOG. CP(0)
  CS=EN*(ALPHA-BETA)
;CSS=EN(T=-IAGE)
  CSS=CS/((K-BETA)*EXP(-ALPHA*IAGE)+(ALPHA-K)*EXP(-BETA*IAGE))
  IPR1=F+CSS/(ALPHA-BETA)*(EXP1+EXP2) ;PLASMA CONC.
  IPR2=A(2)/V1*K21/K12+CSS/(ALPHA-BETA)*(EXP3-EXP4);TISSUE CONC.
  
RZ=CSS/CLE
;ENDOG. RATE
  IDIF=CP-IPR1
  W=(1+IPR1*IPR1*THETA(9)*THETA(9))**0.5
  Y=IPR1+W*THETA(10)*ERR(1)
$THETA
.
.
.
$THETA
$SIGMA 1
FIXED
;VARIANCE FOR ERR(1)
$EST NOABORT NUMERICAL SLOW METHOD=1 INTERACTION LAPLACIAN POSTHOC
    SIG=6 MAX=9999 PRINT=1 MSFO=VER1.MSF
$COVARIANCE MATRIX=S SLOW COMPRESS PRINT=E
$TABLE ID TIME ALPHA CLD CLE BETA V1 RZ NOPRINT FILE=VER1.TAB
$TABLE ID TIME C01 ER=COM(1) EN CSS IPR1 IPR2 NOPRINT FILE=VER1.TAB
$TABLE ID TIME IAGE K12 K21 K R1 IDIF NOPRINT FILE=VER1.TAB
$SCAT CP VS IPR1 UNIT